AWS A5.35/A5.35M pdf free download.Covered Electrodes for Underwater Wet Shielded Metal Arc Welding.
2.2 The following ANSI standard is referenced in the mandatory clauses of this document:
(1) ANSI Z49, I, Safe/v in Welding, Culling and Allied Processes
2.3 The following ASTM International standards are referenced in the mandatory clauses of this document:
(I) ASTM A36/A36M, Standard Specification for Carbon Siruciurul Steel:
(2) ASTM E8IE8M, Standard Test Methods for Tension Testing of Metallic Materials:
(3) ASTM E29. Standard Practice for Using Signzficaiit Digits in Test Daia to Determine onforinance with
Specifications:
(4) ASTM E94, Standard Guide for Radiographic Examination;
(5) ASTM E65/E I 65M, Standard Practice for Liquid Penet rant £wininaiion for General Industry;
(6) ASTM E353, Standard Test Methods for Chemical Analysis of Stainless, Heat-Resisting, Maraging, and Oilier Similar C’hromiu,n—Nickel- iron A llovs;
(7) ASTM E354, Standard Test Methods for Chemical Analysis of High-Temperature. Electrical, Magnetic, and Oilier Similar Iro,,, Nickel, and Cobalt Alloys;
(8) ASTM E4 1 5. Standard Test Method for Atomic Lm,ssion Vacuum Spectromeiric Analysis of ‘arbon and LowAlloy Steel; and
(9) ASTM E709, Standard Guide for Magnetic Particle Testing.
2.4 The following ISO standards are referenced in the mandatory clauses of this document:
(I) ISO 80000- 1, Annex B, Rule A, Quantities and Units— – Part I: General
2.5 The following Military Standard (MIL) is referenced in the mandatory clauses of this document:
(I) MIl-STD-2O35A, Nondestructive Testing Acceptance Criteria
3. Classification
3.1 Electrode Classification. The welding electrodes covered by this specification utilize the following system to classify
the welding electrodes covered:
(I) Type of current (SeeTable I)
(2) Filler metal type by general chemical composition (See Table 1)
(3) AWS classification of electrode by AWS specification, when applicable (See Table 2)
(4) Weld metal integrity (Y), based on soundness and mechanical properties (See Table 2)
(5) Welding position (Z) (See Table 3)
3.2 Examples of electrode classification. The following are four examples of electrode classification:
(I) tTvF:oo13-2A: Ferritic steel electrode (Table 1), similar to the E60 13 classification of AWS A5. I (Table 2), meeting the Level 2 quality standards (Table 2), qualified for all position welding (Table 3).
(2) UWE7OI4- IF: Ferritic steel electrode (Table 1), similar to the E70 14 classification of AWS A5. I (Table 2), meeting the Level I quality standards (Table 2). qualified for the flat position only (Table 3).
(3) UWF3IO-16-3H: Austenitic stainless steel electrode (Table I), similar to the E3 10-16 classification of AWS A5.4 (Table 2), meeting the Level 3 quality standards (Table 2). qualified for flat and horizontal welding only (Table 3).
(4) UWENiXX-IA: Nickel electrode (Table 1), meeting the Level I quality standard.s (Table 2), qualified for all position welding (Table 3).
7. Auxiliary Coating Integrity
Auxiliary coatings shall be uniform with no breaks or flaking which wouki degrade electrode perlormance. I he auxihary coatings shall be applied so as to provide complete coverage of the electrode. They shall extend from at least 1/16 in jI .5 niml beyond the covering on the grip end and shall completely seal the arc end. The auxiliary coatings shall not interfere with electrical continuity between the electrode and the electrode holder.
8. Summary of Tests
8.1 Testing. Testing for conformance to this specification shall be as required by Tables 4 and 5. This testing represents only the electrode chemical composition and diameter, method of manufacture, and auxiliary coating system tested. Any changes to the electrode chemical composition or diameter, method of manufacture (including electrode core wire and flux formulation), formulation of auxiliary coatings, or any addition or deletion of an auxiliary coating, shall require retesting for conformance to the specification; the modified electrodes shall be identified using a different or modified designation from the original.
All test assemblies shall be tested in the as-welded condition; no form of heating shall be used on any test assembly after welding. Grinding is not permitted on the weld reinforcement except for the purpose of magnetic particle testing (MT) or liquid penetrant testing (PT), and only after the weld has passed visual testing (VT).AWS A5.35/A5.35M pdf download.